Product
Specification |
Description |
| Conductivity |
| Range |
... to 2.000 µS/cm ; ... to 20.00 µS/cm ;
... to 200.0 µS/cm ; ... to 2000 µS/cm ;
... to 20.00 mS/cm ; ... to 200.0 mS/cm ;
... to 1000 mS/cm |
| Resolution |
0.001 µS/cm ; 0.01 µS/cm ;
0.1 µS/cm ; 1 µS/cm ;
0.01 mS/cm ; 0.1 mS/cm ;
1 mS/cm |
| Accuracy |
±1 % of full scale reading (±2 % >500 mS/cm) |
| Temperature |
| Range |
-10.0 to 125.0 ºC (14.0 to 257.0 ºF) |
| Resolution |
0.1 ºC / 0.1 ºF |
| Accuracy |
±0.5 ºC / ±1.0 ºF |
| Sensor |
Pt100/Pt1000 (jumper selectable); 2 or 3 wire |
| Compensation |
Auto/manual (normalized at 25 ºC) |
| Set
Point And Controller Functions |
Set Point 1 (SP1) /
Set Point 2 (SP2) |
... to 2.000 µS/cm or ... to 20.00 µS/cm or
... to 200.0 µS/cm or ... to 2000 µS/cm or
... to 20.00 mS/cm or ... to 200.0 mS/cm or
... to 1000 mS/cm |
| Switching Conductivity Hysteresis |
0 to 10 % of full scale |
Function (Switchable)
|
P/PI control (pulse length/pulse frequency/proportional integral); limit control; off |
| Adjustable Period With Pulse Length Controller |
0.5 to 20 sec |
| Adjustable Period With Pulse Frequency Controller |
60 to 120 pulse/min |
Integral Action Time (IAT)
|
0 to 999.9 min |
| Pickup/Dropout Delay |
0 to 2000 sec |
| Wash Cycle |
0.1 to 200.0 hr |
| Wash Duration |
1 to 2000 sec |
| Contact Outputs |
1 SPDT, 3 SPST relays |
| Switching
Voltage/ Current/Power |
1/8 HP: at 125 VAC / max. 0.74 A / max. 93 VA
1/8 HP: at 250 VAC / max. 0.37 A / max. 93 VA |
| Alarm
Functions |
| Function (Switchable) |
Steady or fleet (pulse) |
| Pickup Delay |
0 to 2000 sec |
Switching Voltage/
Current/Power |
1/8 HP: at 125 VAC / max. 0.74 A / max. 93 VA
1/8 HP: at 250 VAC / max. 0.37 A / max. 93 VA |
| Electrical Data & Connections: |
| Transmitter Function |
Two 0/4 to 20 mA scalable outputs for Conductivity and temperature, galvanically isolated |
| CU 22 Function |
22 mA current output |
| Isolated Output Voltage |
12 V ±0.5 V (max. 50 mA) |
| Hold Function Switch |
To freeze output current and deactivate control relays |
| Load |
Max. 600 Ohm |
| Conductivity Input |
2-cell/4-cell terminal |
| Connection Terminal |
5-pin, 8-pin, 9-pin &
13-pin terminal,
detachable blocks
(For TSCONCTP2000W) |
5-pin, 9-pin &
19-pin terminal,
detachable blocks
(For TSCONCTP2000P) |
| Display |
LCD
|
UV coat, backlit 14 segments display with symbols for status information |
| Backlight |
On/off selectable with four level of brightness control
|
| Power Supply |
| Input |
80 to 250 VAC/DC ; 50/60 Hz ; 10 VA |
| Main Fuse |
315 mA, anti-surge, 250 V |
| Pollution Degree |
2 |
| Transient Overvoltage Category |
II |
| EMC Specifications |
| Emitted Interference |
According to EN 61326 |
| Immunity
To Interference |
According to EN 61326 |
| Environmental
Conditions |
| Operating Temperature Range |
0 to 40 ºC |
| Max. Relative Humidity |
80 % up to 31 ºC decreasing linearly to 50 % at 40 ºC |
| Mechanical
Specifications |
| Dimensions (WxHxD) |
144 x 144 x 110 mm
(For TSCONCTP2000W) |
96 x 96 x 175 mm
(For TSCONCTP2000P) |
| Weight |
745 g (unit) /
1100 g (packed)
(For TSCONCTP2000W) |
550 g (unit) /
950 g (packed)
(For TSCONCTP2000P) |
| Ingress Protection |
IP66 (NEMA 4X)
(For TSCONCTP2000W) |
IP54 (front panel)
(For TSCONCTP2000P) |