alpha-COND 500
1/4-DIN 2-Wire Conductivity Transmitter


 

 

Product Features

:: New Design with Isolated Output - The alpha 500 series transmitter prevents output interference due to electrical noise or leakage from the input source. Cross talk between multiple transmitters in the same loop is also eliminated.
   
:: Out-of-range Output Current Indicator - Monitor your process effectively using the optional out-of-range current indicator. When the monitored value exceeds the measurement
range, the alpha 500 Transmitter indicates an out-of-range measurement by emitting a 3.8
mA output current.
   
:: Hold Output Current Indicator - Use the optional HOLD output current indicator for your process control purposes. Configure the transmitter to emit the pre-set 22 mA output current to indicate ‘HOLD’ mode during calibration or set up mode.
   
:: Scalable 4/20 mA Current Output - Assign Conductivity values at 4 and
20 mA for better resolved output at chart recorder or other peripheral devices.
   
:: Custom Dual Display LCD - Primary and secondary display are available for simultaneous display of Conductivity and Temperature values. Allows instantaneous viewing of measured readings and transmitter set up configurations.
   
:: Easy Push Button Operation - Simply calibrate or adjust setup configuration with just a few touches of the buttons. The alpha CON 500 push-button offset adjustment makes calibration simple.
   
:: Temperature Compensation - Compensates variance in the measured readings due to temperature fluctuations, either Automatically (with Pt 100) or Manually (Process and Calibration temperatures can be set separately).
   
:: Panel or Wall Mount, IP65 Weatherproof Housing - The alpha 500 series transmitter has the
flexibility to be mounted on the wall or in a control panel. In addition, the IP65 rated housing
allows the transmitter to be installed outdoors or indoors. Mounting accessories are included
for both types of mounting.
   
:: DC Voltage - Transmitters operate on a 12 to 24V D.C. power supply and multiples can be installed in a serial loop. Operations are not disrupted even if one of the transmitters requires service.
   

Specifications

Product Specification

Description
Conductivity range R1 (R2): 0-20 µS/cm
R2 (R3): 0-200 µS/cm
R3 (R4): 0-2000 µS/cm
R4 (R5): 0-20 mS/cm
R5 (R6): 0-200 mS/cm
Resolution 0.01 µS/cm
0.1 µS/cm
1 µS/cm
0.01 mS/cm
0.01 mS/cm
0.1 mS/cm
Accuracy ±1% of full scale reading in respective range
Temperature -10 °C to 125 °C (14 °F to 257 °F)
Resolution 0.1 °C (0.1 °F)
Relative Accuracy ±0.5 °C (±0.9 °F)
Sensor Pt100 (3 wire / 2 wire)
Temperature Compensation Auto/Manual
Cell Constant User-selectable (0.10 to 10.00)
Temperature Coefficient 0 to 10% (selectable)
Normalisation Temperature 20.0 °C to 25 °C
Display Dual Display Custom LCD
Power Requirements 110 or 220 VAC to 9 V DC Adapter
Dimension 96 x 96 x 66 mm (3.78 x 3.78 x 2.6 inch)
Weight 210 g

Order Information

Order No.

Item
TSCONCTP0500 alpha COND 500 Conductivity 2-Wire Transmitter with 4-20mA Output and 12-24 VDC (Unit only)

 Sales Enquiry
 Service Enquiry

Products > By Type > 2-Wire Transmitters Series

 


Search Our Site
Product Search



Related Information

 Worldwide Offices

 Online Enquiry

 

 

 

 

 

Thermo Fisher Scientific Inc.

  Sitemap   Disclaimer   Privacy Policy

Copyright (c) 2005. Eutech Instruments Pte Ltd. All rights reserved. Powered by Xirlynx Innovations