Product Features
CUSTOM DUAL DISPLAY LCD
Primary and secondary displays are available
for simultaneous display of Conductivity and
Temperature values. Allows instantaneous viewing
of measured readings and setup configurations.
EASY PUSH-BUTTON OPERATION
Simply calibrate or adjust setup configuration
with just a few touches of the buttons. Push-button
offset adjustment makes calibration simple
in the conductivity models.
TEMPERATURE COMPENSATION
Compensates variance in the measured readings
due to temperature fluctuations, either Automatically
(with Pt 100) or Manually (Process and Calibration
temperatures can be set separately).
PANEL OR WALL MOUNT,
IP65 WEATHERPROOF HOUSING
Meters can be mounted on the wall or in a
control panel. In addition, the IP65 rated
housing allows the meter to be installed outdoors
or indoors. Mounting accessories are included
for both types of mounting.
EASY TO USE CONTROLLER
FUNCTIONS
Two switching contacts acting as set-point
relays simplify your task of controlling various
processes. Separately adjustable high and
low set-point hysteresis ensure chatter-free
signal at the set-points.
ADVANCED FEATURES FOR
BETTER CONTROL
Ability to set a time-delay up to 2000 seconds
eliminates unneeded control and prevents false
alarms, making it ideal for industrial environments.
BACK-LIT UV LIGHT PROTECTED
LCD
Back-lit display ensures easy reading even
in the dark. UV light protection minimises
adverse effect of exposure to sunlight.
Specifications
|
Product
Specification |
Description |
| Conductivity
range |
*(R1):
0-2 µS/cm
R1 (R2): 0-20 µS/cm
R2 (R3): 0-200 µS/cm
R3 (R4): 0-2000 µS/cm
R4 (R5): 0-20 mS/cm
R5 (R6): 0-200 mS/cm |
| Resolution |
0.001
µS/cm
0.01 µS/cm
0.1 µS/cm
1 µS/cm
0.01 mS/cm
0.1 mS/cm |
| Accuracy |
±1%
of full scale reading in respective
range |
| Temperature |
-10
°C to 125 °C
(14 °F to 257 °F) |
| Resolution |
0.1
°C
(0.1 °F) |
| Relative
Accuracy |
±0.5
°C
(±0.9 °F) |
| Sensor |
Pt100
/ Pt1000 (3 wire / 2 wire) (selectable) |
| Temperature
Compensation |
Auto/Manual
(reference at 25 °C) |
| Cell
Constant |
User-selectable
(0.10 to 10.00) |
| Temperature
Coefficient |
0
to 10% (selectable) |
| Normalisation
Temperature |
25
°C |
| Controller
Function |
Limit
Control |
| Relay
Operating Parameters |
LO
(Relay active when measured value <
set point)
HI (Relay active when measured value
> set point |
| Time
Delay |
0
to 2000 seconds |
| Switching
Conductivity Hysteresis |
0
to 10% of full scale |
| Contact
Output |
2
SPST relay |
| Switching
Voltage/Current Power |
Max
250VAC/Max 3A/MAX 600 VA |
| Display |
Dual
Display Custom LCD |
| Backlight |
On/Off
selectable |
| Power
Requirements |
110
or 220 VAC to 9 V DC Adapter |
| Dimension |
96
x 96 x 66 mm (3.78 x 3.78 x 2.6 inch) |
| Weight |
210
g |
Order Information
|
Order
No. |
Item |
| TSCONCP0560 |
alpha
COND 560 Conductivity Controller with
2 relay outputs and 110 & 220VAC
to 9VDC adapter |
Sales
Enquiry
Service
Enquiry
Products > By Type > Controllers