Home

Products > Electrodes > Process

Browse by parameter:
pH
ORP
Conductivity
Resistivity
Dissolved Oxygen

pH

Model
pH
Range
Operating
Temperature
Temperature Sensor
Potential
Matching Pin

0 to 14

0 to 80 °C /
32 to 176 ºF

Pt 100

Platinum

0 to 14

0 to 80 °C /
32 to 176 ºF

Pt 100

Platinum

0 to 14

0 to 80 °C /
32 to 176 ºF

Pt 100

Platinum

0 to 14

0 to 80 °C /
32 to 176 ºF


Platinum

0 to 14

0 to 110 °C /
32 to 230 ºF
high temp.



0 to 14,
HF resistant


0 to 80 °C /
32 to 176 ºF




0 to 14


0 to 80 °C /
32 to 176 ºF




0 to 14


-5 to 95 °C /
23 to 203 ºF


NTC 300


SS316

ORP

Model
ORP
Range
Operating
Temperature
Pressure Tolerance
Potential
Matching Pin

±1000 mV

0 to 80 °C /
32 to 176 ºF

6 bar
(87 psi)

Platinum

±1000 mV

0 to 80 °C /
32 to 176 ºF

6 bar
(87 psi)

Platinum

±1000 mV

-5 to 95 °C /
23 to 203 ºF

6.9 bar
(100 psi)

SS316

Conductivity

Model
Conductivity
Range
Operating
Temperature
Cell
Constant, K
Pressure Rating
at 25 ºC

Up to 500 mS/cm

-5 to 100 °C /
23 to 212 ºF

0.3, 4-cell

6 bar
(87 psi)

0.055 to 20 µS/cm

-5 to 50 °C /
23 to 122 ºF

0.01, 2-cell

3.4 bar
(50 psi)

0.055 to 20 µS/cm

-5 to 80 °C /
23 to 176 ºF

0.01, 2-cell

5.5 bar
(80 psi)

0.055 to 20 µS/cm

-5 to 50 °C /
23 to 122 ºF

0.01, 2-cell

3.4 bar
(50 psi)

0.055 to 20 µS/cm

-5 to 80 °C /
23 to 176 ºF

0.01, 2-cell

5.5 bar
(80 psi)

0.5 to 200 µS/cm

-5 to 50 °C /
23 to 122 ºF

0.1, 2-cell

3.4 bar
(50 psi)

0.5 to 200 µS/cm

-5 to 150 °C /
23 to 302 ºF

0.1, 2-cell

6.8 bar
(100 psi)

0.01 to 100 mS/cm

-5 to 50 °C /
23 to 122 ºF

1.0, 2-cell

3.4 bar
(50 psi)

0.01 to 200 mS/cm

-5 to 120 °C /
23 to 248 ºF

1.0, 2-cell

6.8 bar
(100 psi)

0.01 to 2 mS/cm

-5 to 50 °C /
23 to 122 ºF

1.0, 2-cell

1 bar
(14 psi)

0.01 to 200 mS/cm

-5 to 120 °C /
23 to 248 ºF

1.0, 2-cell

6.8 bar
(100 psi)

Resistivity

Model
Conductivity
Range
Operating
Temperature
Cell
Constant, K
Pressure Rating
at 25 ºC

0.055 to 20 µS/cm

-5 to 50 °C /
23 to 122 ºF

0.01, 2-cell

3.4 bar
(50 psi)

0.055 to 20 µS/cm

-5 to 80 °C /
23 to 176 ºF

0.01, 2-cell

5.5 bar
(80 psi)

0.055 to 20 µS/cm

-5 to 50 °C /
23 to 122 ºF

0.01, 2-cell

3.4 bar
(50 psi)

0.055 to 20 µS/cm

-5 to 80 °C /
23 to 176 ºF

0.01, 2-cell

5.5 bar
(80 psi)

0.5 to 200 µS/cm

-5 to 50 °C /
23 to 122 ºF

0.1, 2-cell

3.4 bar
(50 psi)

0.5 to 200 µS/cm

-5 to 150 °C /
23 to 302 ºF

0.1, 2-cell

6.8 bar
(100 psi)

0.01 to 100 mS/cm

-5 to 50 °C /
23 to 122 ºF

1.0, 2-cell

3.4 bar
(50 psi)

0.01 to 200 mS/cm

-5 to 120 °C /
23 to 248 ºF

1.0, 2-cell

6.8 bar
(100 psi)

Dissolved Oxygen

Model
Dissolved
Oxygen
Range
Operating
Temperature
Pressure
Rating
Type

0.50 to 20 ppm

0 to 50 ºC /
32 to 122 ºF

6 bar
(87 psi)

Galvanic

0.03 to 20 ppm

0 to 50 ºC /
32 to 122 ºF

6 bar
(87 psi)

Galvanic

0.04 ppm to saturation

0 to 60 ºC /
32 to 140 ºF

4 bar
(58 psi)

Amperometric

0.01 ppm to saturation

0 to 130 ºC /
32 to 248ºF

4 bar
(58 psi)

Amperometric


 

Search Our Site
Product Search



Related Information

 Worldwide Offices

 Online Enquiry

 

 

 

 

Thermo Fisher Scientific Inc.

  Sitemap   Disclaimer   Privacy Policy

Copyright (c) 2005. Eutech Instruments Pte Ltd. All rights reserved. Powered by Xirlynx Innovations