Featuring auto-standardization, auto-calibration and auto-ranging capabilities, the Eutech CON 2700 accepts 2-cell and 4-cell electrodes, allowing a broad range of measurement at up to ±1 % full scale accuracy. Meter comes with a multi data screen that shows Conductivity readings, temperature, electrode status, calibration points, date and time all at once.

:: Choose auto-calibration with preset values for quick easy calibration, or manual multi-point calibration for greater accuracy
   
:: Easy standardization with auto-standardization feature – detect the exact cell constant value of your electrodes with the press of a button
   
:: Quick, easy electrode diagnosis with the effective cell constants display
   
:: Replatinization in 5 minutes with the built-in replanitization circuit
   
:: Non-volatile memory holds up to 500 data points – time and date-stamped for GLP compliance
   
:: Bi-directional RS232 for easy data transfer to computer
   
:: Cal-due alarm – no more out-dated calibrations!
   
:: Auto-logging function for convenient continuous monitoring
   
:: Limit alarm alerts when reading falls out of range
   
:: Password protection for setup and calibration

Applications

• Environmental studies • Chemical laboratories • Quality assurance testing
• Food science • Ecological studies • Education institution

Specifications

Product Specification Description
Conductivity  
Range 0.050 µS to 500.0 mS
Resolution 0.01 / 0.1 µS ; 0.001 / 0.01 / 0.1 mS
Accuracy ±1 % full scale
Cal. Points Up to 5
Cell Constant 0.010 to 10.000
TDS  
Range (Depending
On TDS Factor)
0.050 ppm to 500 ppt
(@ TDS factor 1.00)
Resolution 0.01 / 0.1 ppm ; 0.001 / 0.01 / 0.1 ppt
Accuracy ±1 % full scale
Cal. Points Up to 5
Salinity  
Range 0.0 to 80.0 ppt
Resolution 0.01 / 0.1 ppm ; 0.001 / 0.01 / 0.1 ppt
Accuracy ±1 % full scale
Resistivity  
Range 2.000 Ohm to 20.0 MOhm
Resolution 0.01 / 0.1 Ohm ; 0.001 / 0.1 kOhm ; 0.01 MOhm
Accuracy ±1 % full scale
Temperature  
Range (Meter) 0.0 to 100.0 ºC / 32.0 to 212.0 ºF
Resolution 0.1 ºC / 0.1 ºF
Accuracy ±0.3 ºC / ±0.5 ºF
Coefficient (Per ºC) Linear & pure ; 0.000 to 10.000 %
Normalization 15.0 to 30.0 ºC / 59.0 to 86.0 ºF
Compensation ATC / MTC
Power Requirements 9 V DC adapter, 1.3 A (100/240 VAC, SMPS)

Order Information

Order No.

Item
ECCON270043S Eutech CON 2700 Meter With 4-Cell Conductivity/ATC Probe (CONSEN9201D)

Configuration include 30X427301 RS232 cable, 100/240 VAC power adapter and an integral electrode holder.

 Sales Enquiry
 Service Enquiry

Products > By Type > Bench Deluxe

 


Search Our Site
Product Search



Related Information

 Worldwide Offices

 Online Enquiry

 


Also in the Eutech 2700 Series
Eutech pH 2700
Eutech Ion 2700
Eutech DO 2700
Eutech PC 2700

Download Brochures
Eutech 2700 Series Family Brochure


Download Instruction Manual
Eutech 2700 Instruction Manual

 

 

 

 

 

Thermo Fisher Scientific Inc.

  Sitemap   Disclaimer   Privacy Policy

Copyright (c) 2005. Eutech Instruments Pte Ltd. All rights reserved. Powered by Xirlynx Innovations