Laboratory
Bench Meters CyberScan
PCD 5500 pH/Ion/ORP/Dissolved Oxygen/Conductivity/Salinity/TDS/
Resistivity/RS232
Dual-Channel Bench Meter
- Extra-Large Durable Touch-Screen LCD
with Backlit provides optimum clear view
of readings even at a distance
- Dual Channel allows user to
measure 2 different parameters and view results on screen simultaneously
- High Resolution and Accuracy (up to ±0.002
pH Accuracy) for precise measurement
- Besides pH and Ion mode, meter reads
DO, Conductivity, Resistivity,
Salinity, TDS with ±0.5% Full Scale Accuracy
- Automatic Calculation of 5-day BOD
Testing,
as well as OUR and SOUR (Specific Oxygen Uptake Rate) testing
- Multi-Point Automatic Calibration
with Auto-Buffer Recognition (up to 5 points) for
hassle-free operation
- Auto-Calibration ensures
effortless operation with no calibration mistake
- Extensive Display Customization
allows viewing of display based on individual preferences for
easy and quick viewing
- Secured Setup Options
explicitly restrict unauthorized tampering of meter settings with
two procedural levels (advanced, basic) for discerning users' needs
- Context-Specific "HELP"
menu prompts and guides user throughout meter's operation with
self-diagnosis messages
- Advanced Setup Menu allows programmable
functions like pH resolution, stability, etc. and viewing of electrode diagnosis - pH
slope/offset,
previous calibration points.
- Automatic Temperature
Compensation (ATC) for best accuracy under fluctuating
temperatures
- Automatic Downloading of data
into memory or computer via a cable at desired time intervals or whenever
reading stabilizes
- Expanded Memory stores and
recalls up to 1000 Data Sets with Password Protection
either manually or on programmable real-time intervals
- Built-In Real-Time Clock stamps stored data and calibration data
with time
& date - meets
standards for GLP purposes
- High/Low Set Point Alarm
alerts once reading outside preset limits
- Automatic Temperature
Compensation (ATC) for best accuracy under fluctuating
temperatures
- FET (Solid-State Non-Glass) pH
electrodes can be used directly without adapter as well as specialty
and standard glass pH electrodes
- Accepts 2-Cell and 4-Cell conductivity
probes and has built-in Replatinizing Circuit
- Automatic Salinity and Barometric
Pressure Compensation for correction in oxygen solubility
- Self-Stirring BOD Probe keeps
sample agitated and measurements consistent
- RS232 Communication interface
for downloading data to a printer or PC for report documentation
- Detachable Electrode Stand
organizes multiple electrodes neatly and holds them firmly in
place
Applications
Laboratory/Industrial: Use for
water quality testing, sewage treatment, food processing (for HACCP
compliance), geological testing. Great for R&D and QC applications
in the food and pharmaceutical industries, paper/pulp processing,
chemical industries and related fields. Suitable for most ASTM and EPA
test procedures.
Water Quality Testing: For
analyzing water hard water, untreated water, drinking water, effluent water,
pool water and
incoming process water. Ideal for all types of quality assurance and
water quality testing.
Environmental: Use to test water
quality, monitor health of aquatic ecosystems, survey surface and
ground water drinking supplies, and meet EPA regulations.
Educational: Perfect for
research labs, suitable for all types of chemistry labs and ecology
studies.
Specifications of
CyberScan PCD 5500 Meter
Product Code
|
EC-PCD5500 |
| pH Range |
-2.000 to 20.000 pH |
| Resolution & Accuracy |
0.1/0.01/0.001 pH &
±0.002 pH |
| mV Range |
-1800 to +1800 mV |
| Resolution & Accuracy |
0.1 mV & ±0.1 mV |
| Ion
Concentration Range |
1 x 10-6 to
9.99 x 1010 |
| Resolution & Accuracy |
4 sig. figures &
±0.17n% |
| DO Range |
0 to 60 ppm, 0 to 600% |
| Resolution & Accuracy |
0.01/0.10% & 0.1% +
1 LSD |
| Conductivity Range |
0 to 300 mS/cm |
| Resistivity
Range |
30 W
to 100 MW |
| Salinity Range |
2 to 42 ppt |
| Accuracy |
±0.5% full scale of
reading |
| Cell
Constant |
0.1, 1.0, 10.0 |
| Temperature Range |
-5.0 to 105.0 °C |
| Resolution & Accuracy |
0.1 °C & ±0.2 °C |
| No. of pH Calibration Points |
Up to 5 standard buffers
from each buffer set
or 3 custom buffers from any of 3 pH buffer options |
| pH Buffer Options |
USA: 2, 4, 7, 10, 12
NIST: 1.68, 4.01. 6.86, 9.18, 12.45
Euro: 1, 3, 6, 8, 10, 12 |
| No. of
Ion Calibration Points |
5 |
| Incremental
methods |
KA, KS, AA, AS |
| Temperature Compensation |
Automatic / Manual (0 to
100 °C) |
| DO
Testing |
5-day BOD, OUR and SOUR
testing |
| Automatic
Barometric Pressure Compensation |
450 to 850 mm Hg |
| Memory |
1000 Data Sets with
Date/Time stamping &
Security password protection |
| Programmable
data storage/output |
On
stable, time and manual |
| Output |
RS232C |
| Print
Interval |
1 - 9,999 sec |
| Electrode
Input |
FET
(solid-state non-glass) or Glass pH electrode |
| Time/Date
Display |
12- or 24-hour format,
date in U.S. or international format |
| Display |
6" x 4.5" Touch-screen Custom LCD with backlit
(Dual Channel) |
| Special
Functions |
Auto-Calibration;
Data-logging options with time/date indexed,
GLP compliance; Replatinising Circuit,
pH slope/offset Display & Self-diagnostic |
| Power |
DC power adapter
110VAC or 220VAC, center negative |


Copyright © 1997 Eutech Instruments Pte Ltd. marketing@eutechinst.com
|