Home Corporate Information What's New Our Products Support Contacts
 
E-Brochure
Instruction Manual
CE Certificate
CyberComm 5000 Software
Laboratory Bench Meters

CyberScan pH 5500 pH/Ion/ORP/RS232 Dual-Channel Bench Meter

  • Extra-Large Durable Touch-Screen LCD with Backlit provides optimum clear view of readings even at a distance
  • Dual Channel allows user to measure 2 different parameters and view results on screen simultaneously
  • High Resolution and Accuracy (up to ±0.002 pH Accuracy) for precise measurement
  • Multi-Point Automatic Calibration with Auto-Buffer Recognition (up to 5 points) for hassle-free operation
  • Auto-Calibration ensures effortless operation with no calibration mistake
  • Extensive Display Customization allows viewing of  display based on individual preferences for easy and quick viewing
  • Secured Setup Options explicitly restrict unauthorized tampering of meter settings with two procedural levels (advanced and basic) for discerning users' needs
  • Context-Specific "HELP" Menu prompts and guides user throughout meter's operation with self-diagnosis messages
  • Advanced Setup Menu allows programmable functions like pH resolution, stability, etc. and viewing of electrode diagnosis - pH slope/offset, previous calibration points.
  • Multi-Language Options like English, French, German and Spanish offer user-interface universally for added convenience
  • Automatic Temperature Compensation (ATC) for best accuracy under fluctuating temperatures
  • Automatic Downloading of data into memory or computer via a cable at desired time intervals or whenever reading stabilizes
  • Expanded Memory stores and recalls up to 250 data sets either manually or on programmable real-time intervals
  • Built-In Real-Time Clock stamps stored data and calibration data with time & date - meets standards for GLP purposes
  • High/Low Set Point Alarm alerts once reading outside preset limits
  • Automatic Temperature Compensation (ATC) for best accuracy under fluctuating temperatures
  • FET (Solid-State Non-Glass) pH electrodes can be used directly without adapter as well as specialty and standard glass pH electrodes
  • RS232 Communication interface for downloading data to a printer or PC for report documentation (Download Software: CyberComm 5000)
  • Detectable Electrode Stand organizes multiple electrodes neatly and holds them firmly in place

Applications

Laboratory/Industrial: Use for water quality testing, sewage treatment, food processing (for HACCP compliance), geological testing. Great for R&D and QC applications in the food and pharmaceutical industries, paper/pulp processing, chemical industries and related fields. Suitable for most ASTM and EPA test procedures.

Educational: Perfect for research labs, suitable for all types of chemistry labs and ecology studies.

Specifications of CyberScan pH 5500 Meter

Product Code

EC-PH5500
pH Range -2.000 to 20.000 pH
Resolution & Accuracy 0.1/0.01/0.001 pH & ±0.002 pH
mV Range -1800 to +1800 mV
Resolution & Accuracy 0.1 mV & ±0.1 mV
Ion Concentration Range 1 x 10-6 to 9.99 x 1010
Resolution & Accuracy 4 sig. figures & ±0.17n%
Temperature Range -5.0 to 105.0 °C
Resolution & Accuracy 0.1 °C & ±0.2 °C
No. of pH Calibration Points Up to 5 standard buffers from each buffer set 
or 3 custom buffers from any of 3 pH buffer options 
pH Buffer Options USA: 2, 4, 7, 10, 12
NIST: 1.68, 4.01. 6.86, 9.18, 12.45
Euro: 1, 3, 6, 8, 10, 12 
No. of Ion Calibration Points  5
Incremental methods KA, KS, AA, AS
Temperature Compensation Automatic/Manual (0 to 100 °C)
Memory 250 Data Sets with Date/Time stamping 
Programmable data storage/output On stable, time and manual
Output RS232C
Print Interval 1 - 9,999 sec
Electrode Input FET (solid-state non-glass) or Glass pH electrode
Time/Date Display 12- or 24-hour format, date in U.S. or international format
Display 6" x 4.5" Touch-screen Custom LCD with backlit (Dual Channel)
Special Functions Auto-Calibration; Multi-language options; 
Data-logging options with time/date indexed, GLP compliance; pH slope/offset Display & Self-diagnostic
Power DC power adapter for 110VAC or 220VAC, center negative



Copyright © 1997 Eutech Instruments Pte Ltd. marketing@eutechinst.com