| Industrial
Process Controllers & Monitors alpha-CON200/TDS200
1/8 DIN Conductivity Controllers
-
User-Customisation
through Scrolling Menu, 14-Segment LED - intuitive
user interface guides user easily through setup functions
-
Multi Measurement
Range- User Selectable
-
Galvanically Isolated 4-20 mA
Output for remote monitoring or hardcopy recording
-
Universal Power
Supply Input from 85 to 250 VAC/DC allows use at multiple
sites and withstands voltage fluctuations
-
Two Level Password
Protection prevents un authorized tampering with settings
-
Automatic Temperature
Compensation with 3-wire Pt 100 system ensures accurate readings
under fluctuating temperatures
-
Adjustable Temperature
Coefficient (0.0 to 5.0%/oC) and selectable cell constants
for more accurate measurements
-
Adjustable Hysteresis
(Dead Band) prevents rapid contact switching near set point
-
Non-Volatile
Memory retains all stored
parameters and calibration data even if power fails
-
Easy Installation
and Wiring with detachable plug-in connectors
Applications
CON 200: Use for plating
tank, rinse water, boiler and cooling tower, feed water and blowdown control,
font solution make-up and control for printing, photographic developing,
chemical production process, ion exchange systems, R.O. systems, industrial
process water, wastewater, dilute acids, salts and bases.
TDS200:
Ideal for drinking water, monitoring and control, hydroponics and
aquaponic solution balance and control, pools and spa hardness and salinity
control.
Specifications
of alpha-CON200/TDS200
Controllers
Conductivity
Range |
Resolution |
TDS
Range (7 separate ranges - software selectable) |
Resolution |
Cell
Constant |
0.00
- 20.00 µS/cm |
0.01
µS/cm |
0.0
- 10.00 ppm |
0.01
ppm |
0.1 |
0.0 - 200.0 µS/cm |
0.1 µS/cm |
0.0 - 100.0 ppm |
0.1
ppm |
0.1 |
0.0 - 200.0 µS/cm |
0.1 µS/cm |
0.0 - 100.0 ppm |
0.1
ppm |
1.0 |
0 - 2000 µS/cm |
1 µS/cm |
0 - 1000 ppm |
1
ppm |
1.0 |
0.00 - 10.00 mS/cm |
0.01 mS/cm |
0.00 - 5.00 ppt |
0.01
ppt |
1.0 |
0.00 - 20.00 mS/cm |
0.01 mS/cm |
0.00 - 10.00 ppt |
0.01
ppt |
1.0 |
0.0 - 200.0 mS/cm |
0.1 mS/cm |
0.0 - 100.0 ppt |
0.1
ppt |
1.0 |
0.0
- 200.0 mS/cm |
0.1 mS/cm |
0.0
- 200.0 ppt |
0.1
ppt |
10.0 |
| Product
Code |
EC-CONCP0200 |
EC-TDSCTP0100 |
Relative
Accuracy |
±1%
of Full Scale |
Cell
Constant |
0.1,
1.0, 10.0 (selectable) |
Calibration |
Push-button
(cell constant
correction function) |
Temperature
Range |
-10°C
to 110 °C |
Resolution
& Accuracy |
0.1
°C & ± 0.5 °C |
Temperature
Compensation |
Automatic
/ Manual (0 to 50 °C) |
Sensor
(for ATC) |
Pt
100 (3-wire) |
TDS
Factor |
Not
Available |
0.40
to 1.00 |
Set-point
and Controller Functions |
Function |
Limit
Control |
Switching
Conductivity/ TDS Hysteresis |
0
- 10% of Full Scale |
Contact
Outputs, Controller |
2
SPDT relays |
Switching
Voltage/ Current/ Power |
Max.
250 VAC/ Max 3A/ Max 600 VA |
Electrical
Data and Connections |
Power
Requirements |
85
to 260 VAC, 50/60 Hz or DC |
Signal
Output/ Load |
4-20
mA galvanically isolated/ 200 ohms |
Connection
Terminals |
3
Detachable connectors (3-pinm 7-pin & 9-pin terminal blocks) |
Main
Fuse |
250
mA, Aniti-surge (BUSSMAN S504+250mA) |
Environmental
Conditions |
Ambient
Temp. Operating Range |
-10
to 50°C |
| Rel.
Humidity |
10 to 95 % (non-condensing)
10
to 95 % (non-condensing) |
IP50
- Protection from dust; limited entrance (no harmful deposit),
but no protection against liquid.
|
Yes |
Mechanical
Specifications |
Dimensions |
96
X 48 X 150 mm |
Weight |
300g
(350g when boxed) |

 
Copyright © 1997 Eutech Instruments
Pte Ltd. marketing@eutechinst.com
|