Distributor Login

Conductivity Measurement Products

Electrical Conductivity (EC) meters measure the capacity of ions in an aqueous solution to carry electrical current. As the ranges in aqueous solutions are usually small, the basic units of measurements are milliSiemens/cm (mS/cm) and microSiemens/cm (µS/cm).

Conductivity is used widely to determine the level of impurities in water supplies for domestic consumption as well as industrial use. Industries that employ this method include the chemical, semi-conductor, power generation, hospitals, textile, iron and steel, food and beverage, mining, electroplating, pulp and paper, petroleum and marine industries.

Specific applications include chemical streams, demineraliser output, reverse osmosis, stream boilers, condensate return, waste streams, boiler blowdown, cooling towers, desalinisation, laboratory analysis, fruit peeling and salinity level detection in oceanography.

Some applications require the measurement of Total Dissolved Solids (TDS) in mg/L, parts per million (ppm) or parts per thousand (ppt). The TDS concentration can be obtained by multiplying the conductivity value with a factor which is empirically determined. The total TDS is a mass estimate and is dependent on the mix of chemical species as well as the concentration while Conductivity is only dependent on the concentration of chemical species.

Eutech offers a wide range of conductivity meters for these various applications.

Browse by product type:

Pocket-Sized Testers >> View Comparison Table

ModelMeter HighlightsParameterRangeMemory
ECTestr 11+ECTestr 11+Waterproof Pocket Tester Large Dual DisplayConductivity.. to 200.0 µS/cm
.. to 2000 µS/cm
.. to 20.00 mS/cm
No
ECTestr 11ECTestr 11Waterproof Pocket Tester Large Dual DisplayConductivity.. to 2000 µS/cm
.. to 20.00 mS/cm
No
ECTestr HighECTestr HighWaterproof Pocket Tester Single DisplayConductivity.. to 19.90 mS/cmNo
ECTestr LowECTestr LowWaterproof Pocket Tester Single DisplayConductivity.. to 1990 µS/cmNo
EcoTestr EC HighEcoTestr EC High
[ Upgrade Version Available ]
Waterproof Economy Pocket Tester Single DisplayConductivity0 to 19.90 mS/cmNo
EcoTestr EC LowEcoTestr EC Low
[ Upgrade Version Available ]
Waterproof Economy Pocket Tester Single DisplayConductivity0 to 1990 µS/cmNo

Economy Handhelds >> View Comparison Table

ModelMeter HighlightsParameterRangeMemory
Thermo Scientific Eutech COND 6+Thermo Scientific Eutech COND 6+
[ NEW! ]
Economical conductivity measurementConductivity/°C/°F0.00 - 19.99 µS/cm
20.00 - 199.9 µS/cm
200.0 - 1999 µS/cm
2.00 - 19.99 mS/cm
20.0 - 200.0 mS/cm
No
Eutech COND 6+Eutech COND 6+Economical conductivity measurementConductivity/°C0 to 19.99 µS/cm
20.0 to 199.9 µS/cm
200 to 1999 µS/cm
2.00 to 19.99 mS/cm
20.0 to 199.9 mS/cm
No
EcoScan CON 6EcoScan CON 6Economical conductivity measurementConductivity/°C.. to 199.9 mS/cmNo

Standard Handhelds >> View Comparison Table

ModelMeter HighlightsParameterRangeMemory
CyberScan CON 11CyberScan CON 11Standard HandheldConductivity/TDS/°C.. to 199.9 mS/cm50 data sets
CyberScan CON 110CyberScan CON 110Expanded memory, RS232 outputConductivity/TDS/°C/°F.. to 199.9 mS/cm100 data sets

Waterproof Handhelds >> View Comparison Table

ModelMeter HighlightsParameterRangeMemory
CyberScan COND 610CyberScan COND 610Waterproof HandheldConductivity/TDS/
Salinity/Resistivity/
°C/°F
.. to 500.0 mS500 data sets
CyberScan COND 600CyberScan COND 600Waterproof HandheldConductivity/TDS/
°C/°F
.. to 200.0 mS500 data sets
Eutech CON 450Eutech CON 450Waterproof HandheldConductivity/TDS/
Salinity/°C/°F
0 to 200 mS500 data sets
CyberScan CON 410
CyberScan CON 410
[ DISCONTINUED ]
Waterproof GLPConductivity/TDS/
°C/°F
.. to 199.9 mS50 data sets
CyberScan CON 400
CyberScan CON 400
[ DISCONTINUED ]
For units manufactured before March 2010
Waterproof GLPConductivity/
°C/°F
.. to 199.9 mS50 data sets
CyberScan CON 400CyberScan CON 400
For units manufactured from March 2010 onwards
Waterproof GLPConductivity/TDS/°C/°F.. to 199.9 mS50 data sets
CyberScan CON 150CyberScan CON 150Waterproof HandheldConductivity/TDS/°C/°F0 to 200 mS150 data sets

Bench Meters

Economy / Deluxe Bench

ModelMeter HighlightsParameterRangeMemory
Eutech CON 700Eutech CON 700Large LCD with dual display economy meterConductivity/TDS/°C/°F.. µS to 200.0 mS100 data sets
CyberScan CON 510CyberScan CON 510
[ Upgrade Version Available ]
Economical, high performanceConductivity/TDS/°C/°F.. to 199.9 mS/cm50 data sets
Eutech CON 2700Eutech CON 2700Graphic LCD with backlight & extensive displayConductivity/TDS/
Salinity/Resistivity/°C/°F
0.050 µS to 500.0 mS500 data sets

Premium Bench >> View Comparison Table

ModelMeter HighlightsParameterRangeMemory
CyberScan CON 1500
CyberScan CON1500
[ DISCONTINUED ]
0.001 resolution, optimum performanceConductivity/TDS/
Resistivity/°C/°F
.. to 500 mS/cm100 data sets
CyberScan CON 6000
CyberScan CON6000
[ DISCONTINUED ]
Windows® CE-driven single channel colour touchscreenConductivity/
Resistivity/
TDS/Salinity
.. to 500 mS/cm10,000 data sets

Process Instruments

ModelMeter HighlightsParameterRangeController Functions
Alpha COND 190
Alpha COND 190
[ DISCONTINUED ]
1/8 DIN panel mount, 2 set points relays, Easy set point adjustment and direct CALConductivity/°C.. to 200 mS/cmLimit Control
Alpha COND 200
Alpha COND 200
[ DISCONTINUED ]
1/8 DIN panel mount, 2 set points relays, Password protection for set point adjustment and calibrationConductivity/°C.. to 200 mS/cmLimit Control
Alpha COND 500
Alpha COND 500
[ DISCONTINUED ]
2-wire transmitter, panel mount or wall mount, ‘out-of-range’ and ‘hold’ indicatorsConductivity/°C.. to 200 mS/cm2-Wire Transmitter
Alpha COND 550Alpha COND 5501/4 DIN panel mount or wall-mount, 3-wire/2-wire selectable, Symmetrical mode of operationConductivity/°C.. to 200 mS/cmMonitor
Alpha COND 560Alpha COND 5601/4 DIN panel mount or wall mount, 2 set points relays, Alarm with time-delay functionConductivity/°C.. to 200 mS/cmLimit Control
Alpha COND 1000Alpha COND 10001/4 DIN panel mount, 2 set points, 1 alarm relayConductivity/°C.. to 199.9 mS/cmLimit or Proportional Control
(Pulse Length or Pulse Frequency)
Alpha COND 2000Alpha COND 20001/2 DIN wall mount, 2 set points, 1 alarm and wash relayConductivity/°C.. to 1000 mS/cmLimit, Proportional or
Proportional Integral Control
(Pulse Length or Pulse Frequency)

Process Electrodes

ModelConductivity RangeOperating TemperatureCell Constant, KPressure Rating at 25°C
EC91346SEC91346SUp to 500 mS/cm-5 to 100°C / 23 to 212°F0.3, 4-cell6 bar (87 psi)
ECCS10001TECCS10001T0.055 to 20 µS/cm-5 to 50°C / 23 to 122°F0.01, 2-cell3.4 bar (50 psi)
ECCS10001TSECCS10001TS0.055 to 20 µS/cm-5 to 80°C / 23 to 176°F0.01, 2-cell5.5 bar (80 psi)
ECCS10001SECCS10001S0.055 to 20 µS/cm-5 to 50°C / 23 to 122°F0.01, 2-cell3.4 bar (50 psi)
ECCS10001SSECCS10001SS0.055 to 20 µS/cm-5 to 80°C / 23 to 176°F0.01, 2-cell5.5 bar (80 psi)
ECCS1001SECCS1001S0.5 to 200 µS/cm-5 to 50°C / 23 to 122°F0.1, 2-cell3.4 bar (50 psi)
ECCS1001SSECCS1001SS0.5 to 200 µS/cm-5 to 150°C / 23 to 302°F0.1, 2-cell6.8 bar (100 psi)
ECCS1010SECCS1010S0.01 to 100 mS/cm-5 to 50°C / 23 to 122°F1.0, 2-cell3.4 bar (50 psi)
ECCS1010SSECCS1010SS0.01 to 200 mS/cm-5 to 120°C / 23 to 248°F1.0, 2-cell6.8 bar (100 psi)
ECCONSEN88XECCONSEN88X0.01 to 2 mS/cm-5 to 50°C / 23 to 122°F1.0, 2-cell1 bar (14 psi)
ECCONSEN89XECCONSEN89X0.01 to 200 mS/cm-5 to 120°C / 23 to 248°F1.0, 2-cell6.8 bar (100 psi)

Laboratory Electrodes

ModelConductivity RangeTemperature RangeSensor TypeReference Type
CONSEN91BCONSEN91B0 to 150 mS0 to 80°CPlatinum pinAg/AgCl sealed
CONSEN91JCONSEN91J0 to 150 mS0 to 80°CPlatinum pinAg/AgCl sealed
CONSEN9103JCONSEN9103J0 to 150 mS0 to 80°CPlatinum pinAg/AgCl refillable
EC620165EC6201650 to 500 mS0 to 70°CPlatinum pinAg/AgCl refillable
CONSEN91WCONSEN91W0 to 150 mS0 to 80°CPlatinum bandAg/AgCl refillable
CONSEN9501DCONSEN9501D0 to 150 mS0 to 80°CPlatinum bandAg/AgCl refillable
93X54610193X546101< 200 µS0 to 80°CPlatinum pinAg/AgCl refillable
93X54610293X546102< 1 mS0 to 80°CPlatinum pinAg/AgCl refillable
CONSEN9203JCONSEN9203J0 to 350 mS0 to 100°C*Platinum bandAg/AgCl refillable
CONSEN9201DCONSEN9201D0 to 350 mS0 to 100°C*Platinum bandAg/AgCl refillable

* Max. constant temp of 75°C; intermittent measurements up to 100°C